Release Notes for MPLAB® ICD 3
In-Circuit Debugger & Device (Production) Programmer
MPLAB® IDE v8.56
DLL and Firmware versions:
MPICD3.dll | v1.0.3.22 | |
MPLAB ICD 3 Suite (OS, FW) | v1.26.26 | (ICD3FW_012626.jam) |
August 13, 2010
Table of Contents
5 Repairs and Enhancements Made in v8.56
7 Powering the Debugger and Target Board
8 Setting Up the Debugger and Target Board
9 Device Programming Considerations
13 Number of Hardware Breakpoints Per Device
Click the link below to see device support for “ICD 3 Debugging” (IC3D) and “ICD 3 Programming” (IC3P).
See "Device Programming Considerations" for special device programming considerations to avoid damage these devices:
PIC24F/H |
dsPIC33F |
For low pin-count devices (8 to 28 pins), a Header board is usually required. See the Header Board Specification (DS51292) or Header help file (hlpHeader.chm) for a list of available headers by device.
For high pin-count devices (40 to 100 pins), a Header board may available, but is not required. See the Header Board Specification (DS51292) or Header help file (hlpHeader.chm) for a list of available headers by device.
This tool has been tested using the following operating systems:
32-Bit: Windows® 2000 SP4, Windows XP SP2, Windows Vista™ and Windows 7 OSs
64-Bit: Windows XP 64, Windows Vista 64 and Windows 7 64 OSs
NOTE: Windows NT® and Windows 98/ME OSs are NOT supported.
The following documents may be found on our website or MPLAB IDE CD-ROM:
· MPLAB ICD 3 In-Circuit Debugger User's Guide (DS51766)
· MPLAB ICD 3 Design Advisory (DS51764)
· Using MPLAB ICD 3 In-Circuit Debugger poster (DS51765)
· Header Specification (DS51292)
· Transition Socket Specification (DS51194)
On-line help (Help>Topics) is also available for this tool:
· Debuggers>MPLAB ICD 3
The default location of the Help file is:
· C:\Program Files\Microchip\MPLAB IDE\ICD 3\hlpMPLABICD3.chm
Bug fixes.
RI-446: Cannot debug PIC16F819 with MPLAB ICD 3.
ICD3-254: PC values does not change when single stepping using MPLAB ICD 3 with PIC12F617.
ICD-249: Unable to enter debug mode with MPLAB ICD 3 using the emulation header for PIC18F/LF13K22, PIC18F/LF14K22, PIC18F/LF13K50 and PIC18F/LF14K50.
ICD3-255: ICD debug reserved resource information in the help file is inconsistent and incorrect across MPLAB ICD 2, MPLAB ICD 3, REAL ICE for PIC16F1xxx devices.
Installation and setup instructions are dependent on your operating system. Open the appropriate file for your OS in a web browser and follow the instructions to install the driver(s).
Notes:
Win 2000/Win XP/Win Vista/Win 7
Find detailed instructions at:
C:\Program Files\Microchip\MPLAB
IDE\ICD3\Drivers\ddicd3.htm
Basic instructions are as follows:
a. automatically for Win 2000/XP.
b. manually
for Win Vista and Win 7. The drivers are located in:
C:\Program Files\Microchip\MPLAB
IDE\ICD3\Drivers
Win XP 64/Win Vista 64/Win 7 64
Find detailed instructions for Win XP 64 at:
C:\Program Files (x86)\Microchip\MPLAB
IDE\Drivers64\XP64\ddxp64.htm
For Win Vista 64:
C:\Program Files (x86)\Microchip\MPLAB
IDE\Drivers64\Vista64\
ddvista64.htm
For Win 7 64:
C:\Program Files (x86)\Microchip\MPLAB
IDE\Drivers64\Win7_64\
ddwin764.htm
Basic instructions are as follows:
1. Install MPLAB IDE v 8.14 or higher (for Win XP/Vista 64) or v8.43 or higher (for Win 7 64).
4.
Follow the “Found New Hardware Wizard” to install the drivers (software)
manually.
C:\Program Files (x86)\Microchip\MPLAB
IDE\Drivers64
The MPLAB ICD 3 debugger is powered through its USB connection to the PC.
The target board is powered from its own supply. With some devices, the debugger can provide power to the target board, but is limited to a voltage range of 3-5v and current of 100 mA.
1. Install the USB drivers on your PC, as discussed above (USB Port Setup). When this is complete, MPLAB ICD 3 debugger should be plugged into a USB port of the PC.
2. If you have not already done so, connect to a target, either directly or through a header board. See on-line help or the user's guide for ways to connect the debugger to a target board.
3. Power the target.
4. Start MPLAB IDE.
5. In MPLAB IDE, select either Debugger>Select Tool>MPLAB ICD 3 or Programmer>Select Programmer> MPLAB ICD. The debugger will automatically connect. Also, the debugger can automatically detect if it has been disconnected/reconnected and if the target has been disconnected/reconnected.
6. The debugger will now be ready for use.
For CodeGuard™ Security Devices
Several 16-bit devices allow customers to define up to 3 programming segments: Boot, Secure and General. The purpose is to allow a customer to place proprietary data (libraries, IP address, etc.) into a protected boot or secure segment. That customer may then transfer these preprogrammed devices to another customer who would use the unprotected general segments.
For more details on CodeGuard Security functionality, please refer to the CodeGuard Security reference manual for 16-bit devices (DS70180) and dsPIC33F/PIC24H and dsPIC30F device programming specifications found on our website.
To program the preprogrammed devices, MPLAB IDE v8.00 and above provides a Secure Segment tab on the Settings dialog, accessed under either the Programmer or Debugger menu. This tab contains the following options:
· Full Chip Erase/Program
· Segment Programming
· Boot, Secure & General Segments
· Secure,General Segments
· General Segment.
The programming function of this tool is now capable of identifying various device segments and their sizes upon connecting the device. Hence, these options allow you to selectively program the program memory segments and thus avoid accidental eraser of preprogrammed proprietary data (Libraries, IP, etc.)
For Non-CodeGuard Security Devices
When programming these devices, bulk erase commands should be issued between successive programming operations, i.e., erase, then program, then erase, then program, etc. Therefore, Microchip advises against multiple-stage programming sessions which may fail to verify. For example, you should NOT do the following sequence with these devices:
The following is a list of known problems. For information on common problems, error messages and limitations, please see Troubleshooting in the online help file for the MPLAB ICD 3 debugger (hlpMPLABICD3.chm).
· Do not connect to more than one MPLAB ICD 3 unit at a time or attempt to connect two MPLAB IDE sessions to the MPLAB ICD 3 debugger.
· If you do not use the included cables, make sure the cables you do use are: (1) not longer than 6 inches for standard communications or errors could result and (2) USB 2.0 compliant if you will be using USB 2.0 communications.
· Using the USB connection on a laptop PC with hibernate mode enabled will lock up the debugger if hibernate mode is entered. Unplug the USB cable from the MPLAB ICD 3 debugger and then plug the cable back in to resume debugging. You may want to disable hibernate mode while using the debugger. From Control Panel, select "Power Options" and disable hibernate mode.
ICD3-55: Above 16MHz, in EC mode, a Reset executes the first few instructions instead of only 1 instruction. Workaround is to add 3 NOPs at the reset vector.
ICD3-198: For the PIC16F505 device, MPLAB ICD3 does not display correct values for TRISC in the SFR window.
ICD3-222: For the headers AC162059, AC162070, AC162096: PIC16F505/506/526 device families you cannot simply switch between MPLAB ICD 2 and MPLAB ICD 3. After using the header with MPLAB ICD 2, it will not work correctly and the calibration memory will be lost. Perform the following steps to get the header working with MPLAB ICD3 again:
· Note the calibration memory while using the header with MPLAB ICD 2 before connecting the header using MPLAB ICD 3
· Connect the header using MPLAB ICD 3 as a Debugger. You will see an invalid calibration memory message in the output window.
· Erase the header using Debugger>Erase Flash Device
· Remove power from the target, wait for approximately 10 seconds, then re-apply power to target.
· Build the project or load the image from a hex file.
· Go to Debugger>Settings>Calibration Memory and select the checkbox "Allow ICD 3 to program calibration memory" and enter the old calibration value in the field.
· Program the header using MPLAB ICD 3.
ICD3-233: EEData memory incorrectly reads "FF" in some memory locations after programming the PIC16F886 at 5V using MPLAB ICD 3.
ICD3-243: ICD3CMD does not work on 64-bit Operating Systems.
RI-400: If you are not able to enter debug mode when power-up timer is enabled for the following devices, please disable power-up timer during the debugging session. (If the final application firmware requires power-up timer enabled, please enable it after the debugging session is complete and program the part with the final application firmware.)
PIC18F4620/4610/2620/2610
PIC18F4680/2680/4681/2681
PIC18F4520/4420/2520/2420
PIC18F4550/2550/4455/2455
PIC18F8490/8410/6490/6410/8390/8310/6390/6310
PIC18F8722/8627/8622/8527/6722/6627/6622/6527
PIC18F2525/4525
PIC18F87K90/PIC18F86K90/PIC18F85K90/PIC18F67K90/PIC18F66K90/PIC18F65K90
PIC18F87K22/PIC18F86K22/PIC18F85K22/PIC18F67K22/PIC18F66K22/PIC18F65K22
· Watch window – It will take 1 cycle for the watch window to update properly for PORTx registers. Use an instruction that reads the port such as ‘MOVFF PORTx, PORTx_copy’ before the breakpoint is reached. This affects the following devices:
PIC18F4620 |
PIC18F84J90 |
PIC18F65J11 |
PIC18F63J90 |
PIC18F84J95 |
PIC18F83J11 |
PIC18F64J90 |
PIC18F85J90 |
PIC18F84J11 |
PIC18F64J95 |
PIC18F63J11 |
PIC18F84J16 |
PIC18F65J95 |
PIC18F64J11 |
PIC18F85J11 |
PIC18F83J90 |
PIC18F64J16 |
PIC18F8722 |
· For the PIC18F14K22 family, MPLAB IDE debug/programming tools will not work below 1.9v. The work-around is to run the device above 1.9v.
· PIC18F2520 MCUs: Table Read Protect (EBTRx) will not work unless Code Protect (CPx) is enabled. Also, once Table Read Protect is enabled, you cannot perform a Verify on the protected block.
· PIC18F45K20/46K20 MCU family: There is a silicon issue that prevents some device revisions from being programmed with "power from programmer". The workaround is to use "power from target" OR increase the capacitance across VDD, VSS (for example to 47uF.)
· For PIC18F8720, MEMCON cannot be read if in a microcontroller mode. This is a silicon issue.
RI-431: Unable to halt at a SW breakpoint on PIC18F/LFK22 and PIC18F/LFK90 using REALICE as a debugger.
SSR 29399: PIC24F devices can start to run after programming but before verification. This can result in a verification failure if the code performs self-write to either program memory or Data EE.
ICD2-81: For PIC24F devices during a programming/verify operation (or subsequent verification operation) of user code that performs self-writes and/or self-erases to program space, a verify sequence may fail if the code execution occurs within the first execution cycles following reset.
Workaround:
Place a delay in your code before the code section that performs the self-write and/or self-erase. The specific delay value may need to be adjusted, but 100 ms would be a conservative value to start out with. Here is a C language example that illustrates the workaround:
int main (void)
{
// Place 100 ms delay here before any self-write/self-erase code
: : :
}
ICD3-225: Upper unimplemented bits in the configuration word for the PIC24FJ64GA004 are being programmed to a '0' instead of a ‘1’.
RI-412: PIC24FJ256DA210 Family: Data Memory not functional unless 96 MHz PLL is enabled. This is a silicon issue that is being worked on.
ICD3-216: For the PIC32 family of devices, MPLAB ICD 3 is unable to reset or single step correctly after a Soft Reset is performed.
· When running in debug mode, selecting Debugger>Reset resets the program, goes to the zero location, and halts. The program does not automatically re-run.
· If porting an existing project using MPLAB ICD 2 to the MPLAB ICD 3 debugger, you must do the following:
· Select Project>Build Options>Project. When the dialog opens, click OK. This is necessary to save new Build Options in the project. Previously there had been a checkbox option for "Link for ICD2" on the MPLAB LINK30 tab. This is now gone and has been replaced by a Build Configurations selection (see below.)
· On the Project Manager toolbar select "Debug" from the Build Configurations drop-down list, or from the Project menu select “Build Configurations” and then “Debug”.
· Rebuild the project (Build All).
· Make sure that table reads/writes are not code protected.
· At low Vdd, bulk erase will not erase code protect bits.
Before setting the Stopwatch between any 2 Software breakpoints, ensure that the total number of Hardware breakpoints being used is always 2 less than the Maximum number of Hardware breakpoints available for the device.
1.
RB0 and RB1 pins:
If the MPLAB ICD 3 debugger is selected as a debugger, it initializes all the
A/D input pins - AN0 (RB0) through AN15 (RB15) pins - as "digital"
pins, by setting all 16 bits in the ADPCFG register.
For example, if EMUD3 and EMUC3 are used as the debug pins on a dsPIC30F2010 device, then bits 0 and 1 of the ADPCFG register must remain set at all times. Similarly, if EMUD and EMUC are used as the debug pins on a dsPIC30F5011 device, then bits 6 and 7 of the ADPCFG register must remain set at all times. In such cases, you must also take proper precaution to isolate the application circuitry from the corresponding A/D pins during debugging.
For example, if AN4 and AN5 are required as analog input pins, then bits 4 and 5 of the ADPCFG register must be cleared.
2.
SLEEP, IDLE, WDT, Clock Switching:
For dsPIC devices, debug operations can be executed on programs which use SLEEP
or IDLE mode, Watchdog Timer, and/or Clock Switching.
3.
Debug during SLEEP or IDLE Mode:
When the device is in SLEEP and IDLE mode and a Halt command is issued, the
MPLAB ICD 3 debugger will wake up the device and halt execution on the
instruction immediately following the PWRSAV instruction.
4. Interrupts:
5.
Break Point Behavior:
If a break point is set on an instruction that follows a taken branch, the
Breakpoint will be triggered even though the branch went elsewhere.
6.
Break Point Behavior and Skidding:
It is possible that a breakpoint halt will exhibit program memory skidding in
that the execution stops N instructions after reaching the breakpoint. The
following definitions are provided and referred to:
· One skid - A breakpoint occurs AFTER the instructions is executed (PC+2)
· Two skid - A break point occurs AFTER the NEXT instruction (PC+4)
Break Point Behavior:
· If a Non-Program-Flow, modifying, Single-Word, Two-Cycle instruction (such as Table or PSV) precedes a break point instruction, then the breakpoint occurs BEFORE the instruction at the breakpoint address is executed (ONE SKID).
· All other instructions have a "TWO SKID", which means the break occurs AFTER the NEXT instruction is executed.
7. The CAN module, unlike the other peripherals, does not get frozen in the following situations:
· during a Halt
· during a stop on a Breakpoint
· after a Single-Step
For example, if you set a Breakpoint and run to it, the CAN module continues to run in the background, and it may seem that data transmissions and receptions have completed immediately.
8.
DISICNT register:
In five dsPIC30F devices (dsPIC30F6010, dsPIC30F6011, dsPIC30F6012,
dsPIC30F6013 and dsPIC30F6014), since the DISICNT register continues to
decrement even when the device is halted by the debugger, the DISICNT value
will always be seen as 0x0000 in the Watch, SFR and File Registers windows. To
monitor the DISICNT value, add code to copy the DISICNT register contents to a
W register or memory location and monitor the value of the corresponding W
register or memory location in the Watch, SFR or File Registers window.
9.
ADCMD bit in PMD1 register:
The user application must not set the ADCMD bit (bit 0 of PMD1 register). This
would lead to incorrect ICD operation.
10.
SPLIM register:
When using the MPLAB ICD 3 debugger as a debugger, your software must
initialize the Stack Pointer Limit register (SPLIM) before using the stack
(device errata).
11.
Single-stepping a DO loop:
In five dsPIC30F devices (dsPIC30F6010, dsPIC30F6011, dsPIC30F6012,
dsPIC30F6013 and dsPIC30F6014), single-stepping through a DO loop in dsPIC30F
assembly code results in the loop getting executed one less time than expected.
12.
Pass Counter feature in Advanced Breakpoints:
For a specified Pass count of 'N', the code will break after 'N+1' occurrences
of the breakpoint instead of 'N' occurrences.
13. If you need to use the Fail-Safe Clock Monitor feature on a dsPIC device when using the MPLAB ICD 3 debugger for debugging your application, a Watchdog Timer Device Reset will occur, even if the Watchdog Timer has not been explicitly enabled in the application. To work around this issue, use the "CLRWDT" instruction in the main loop of your application code. This will ensure that the Watchdog Timer gets cleared before it causes the device to reset.
Refer to the data sheet for more information.
Due to the built-in in-circuit debugging capability of ICE devices, and the ICSP function offered by the debugger, the MPLAB ICD 3 in-circuit debugger uses on-chip resources when debugging, i.e., some device resources are reserved for use by the debugger.
Refer to the on-line help for the most up-to-date list of resources used by the debugger.
To see the number of breakpoints supported for your device and the number of breakpoints used in your project, use the Device Debug Resource toolbar. For more on this toolbar, see MPLAB IDE on-line help.
Breakpoint support per device family is as follows:
PIC18F devices – 1 breakpoint
PIC18F Enhanced devices – 3 breakpoints
PIC18FXXJ devices – 3 or 5 breakpoints*
dsPIC30F devices – 2 breakpoints
dsPIC33F/PIC24 devices – 4 breakpoints
PIC32MX devices – 6 breakpoints
* There is a limitation for these devices that only 1 data capture is available.